Each room's cooling load on a hot day in watts and BTU/h, the split unit size that covers it, and whether its heating would keep the room warm in winter.

An estimate of each room's cooling load to choose air-con units by, not an air-conditioning design. Fitting a split unit's refrigerant circuit is for a certified installer (F-gas in the UK, an attestation de capacité in France, a certificado de gases fluorados in Spain), and its power supply is electrical work.

Sets the places to pick summer and winter temperatures from, and a common construction.

Rooms

Room 1

Inside, cooled. 24 °C is usual.

Walls with the outside behind them: one is the longer wall, two a corner room.

WindowsEach window's glass and frame, which way it faces, and what shades it. The sun through them is usually most of the load.

Doors to the outside, glazed ones too.

Usually in the room when it's hot.

Their heat: a TV, a computer, an oven.

Below
Above
The heat air-con is usually designed for there, and the cold its heating should cope with. Estimates.
External walls

U-values used: solid 2.1, unfilled cavity 1.6, filled or insulated 0.5, timber frame 0.4, recent 0.28 W/m²K.

Windows

U-values used: 4.8, 2.8, 1.4 and 1.0 W/m²K. Share of the sun let through (g): 0.85, 0.75, 0.63 and 0.5.

Loft insulation

For rooms with a roof or loft above them, which the sun heats.

Ground floor

Only for the winter heating check: a floor on the ground keeps a room cool in summer.

Built

Newer homes are more airtight, so less hot air comes in.

Added to each room for a hotter day than usual or a room that's hard to measure.

Cooling estimate

Cooling needed

1,690 W

  • In BTU/h5,765 BTU/h
  • Room 1, living room: a 7,000 BTU/h (2 kW) unit1 unit
How it's worked out
  1. Room 1, living room: 4.5 m × 3.6 m, 2.4 m high: floor 16.2 m², volume 38.88 m³
  2. 28 °C outside, 24 °C inside: a difference (ΔT) of 4 °C
  3. 2 external walls: 8.1 m × 2.4 m = 19.44 m², less 2.52 m² of windows and doors = 16.92 m²
  4. Walls: 16.92 m² × U 0.5 W/m²K × (4 + 4 for the sun on it) °C = 68 W
  5. Windows: 2.52 m² × U 2.8 W/m²K × 4 °C = 28 W
  6. Sun through a south-facing window: 1.26 m² × 350 W/m² × g 0.75 = 331 W
  7. Sun through a west-facing window: 1.26 m² × 500 W/m² × g 0.75 = 473 W
  8. 3 people: 3 × 70 W = 210 W of heat, and 3 × 50 W = 150 W of moisture (latent)
  9. Appliances and lights: 200 W
  10. Air: 0.33 × 1.5 air changes an hour × 38.88 m³ × 4 °C = 77 W
  11. Room 1, living room: 1,386 W of heat + 150 W of moisture = 1,536 W, plus a 10% margin = 1,690 W (5,765 BTU/h)
  12. 1,690 W → a 7,000 BTU/h (2 kW) unit, the next standard size up
  13. Heating check: in winter, at 21 °C inside and -3 °C outside, the room loses 645 W through its fabric + 462 W in air, plus the 10% margin = 1,217 W, by the radiator calculator's method
  14. The unit heats about 2,600 W at 7 °C outside; at -3 °C, 1.5% less for each degree colder (at least half kept): × 0.85 = 2,210 W
  15. That covers the room's heat loss.
  16. Every window is taken at its own peak sun. The sun is never at its peak on two sides at once, so for a room with windows on opposite sides this errs high.
  17. Moisture from outside air isn't counted, only people's. On humid days, by the sea especially, a unit spends more of its capacity drying the air.
  18. The room needs 1,690 W × 3.412 = 5,765 BTU/h. A multi-split's outdoor unit serves several rooms and isn't their sum: the installer sizes it.
  19. An estimate from typical figures, not an air-conditioning design. A split unit's refrigerant circuit is for a certified installer: F-gas certified in the UK, holding an attestation de capacité in France, and in Spain with a certificado de gases fluorados and registered as a RITE installer.

An estimate, not an air-conditioning design. Typical U-values, sun on glass and air changes stand in for your home's own. The maker's figures decide what a unit really gives, in cooling and heating.

Save this to your project

RenovU keeps your calculations with your rooms, tasks and budget. It opens soon: join the waitlist and we'll tell you when you can save results like this one.

What it works out

This estimates how much heat each room takes in on a hot day, its cooling load, in watts and BTU/h, and the split air-con unit size that covers it. Add one room or several: you get each room's figure and a unit for it, which is what you choose air-con by.

It also checks whether the unit's heating would keep the room warm in winter, since most split units are heat pumps too. It's an estimate to compare units with, not an air-conditioning design. A split unit's refrigerant circuit is for a certified installer, and its power supply is electrical work (see our electrical guidance).

How it works

Heat comes into a room several ways. Sun through the windows is usually the most: each window's area × the peak sun on glass facing its way × the share its glazing lets through (g) × its shading. A west window gets 500 W/m² at its peak, a north one 100, a roof window 650.

Through the fabric: the external walls and doors take U-value × area × (the outside temperature less the inside, plus 4 °C for the sun on them), a ceiling under a roof plus 12 °C, the windows the plain difference. Ground floors and walls to other rooms are left out.

From inside: each person gives about 70 W of heat and 50 W of moisture, and appliances and lights their own watts. And in air: 0.33 × the room's air changes an hour × its volume × the temperature difference. A margin goes on top. One watt is 3.412 BTU/h, and one kilowatt 860 frigorías/h.

Each room gets the next standard unit size up: 7,000, 9,000, 12,000, 18,000 or 24,000 BTU/h (2.0 to 7.0 kW). Then its heat loss on a cold day, worked out as the radiator calculator does, is set against the unit's heating, which drops by about 1.5% for each degree below 7 °C outside.

A worked example

A living room 4.5 m by 3.6 m, 2.4 m high, with two external walls, a 1.26 m² window facing south and another facing west, no shading, 3 people and 200 W of appliances and lights, another room above, and 28 °C outside in summer (-3 °C in winter).

  1. Room 1, living room: 4.5 m × 3.6 m, 2.4 m high: floor 16.2 m², volume 38.88 m³
  2. 28 °C outside, 24 °C inside: a difference (ΔT) of 4 °C
  3. 2 external walls: 8.1 m × 2.4 m = 19.44 m², less 2.52 m² of windows and doors = 16.92 m²
  4. Walls: 16.92 m² × U 0.5 W/m²K × (4 + 4 for the sun on it) °C = 68 W
  5. Windows: 2.52 m² × U 2.8 W/m²K × 4 °C = 28 W
  6. Sun through a south-facing window: 1.26 m² × 350 W/m² × g 0.75 = 331 W
  7. Sun through a west-facing window: 1.26 m² × 500 W/m² × g 0.75 = 473 W
  8. 3 people: 3 × 70 W = 210 W of heat, and 3 × 50 W = 150 W of moisture (latent)
  9. Appliances and lights: 200 W
  10. Air: 0.33 × 1.5 air changes an hour × 38.88 m³ × 4 °C = 77 W
  11. Room 1, living room: 1,386 W of heat + 150 W of moisture = 1,536 W, plus a 10% margin = 1,690 W (5,765 BTU/h)
  12. 1,690 W → a 7,000 BTU/h (2 kW) unit, the next standard size up
  13. Heating check: in winter, at 21 °C inside and -3 °C outside, the room loses 645 W through its fabric + 462 W in air, plus the 10% margin = 1,217 W, by the radiator calculator's method
  14. The unit heats about 2,600 W at 7 °C outside; at -3 °C, 1.5% less for each degree colder (at least half kept): × 0.85 = 2,210 W
  15. That covers the room's heat loss.
  16. Every window is taken at its own peak sun. The sun is never at its peak on two sides at once, so for a room with windows on opposite sides this errs high.
  17. Moisture from outside air isn't counted, only people's. On humid days, by the sea especially, a unit spends more of its capacity drying the air.
  18. The room needs 1,690 W × 3.412 = 5,765 BTU/h. A multi-split's outdoor unit serves several rooms and isn't their sum: the installer sizes it.
  19. An estimate from typical figures, not an air-conditioning design. A split unit's refrigerant circuit is for a certified installer: F-gas certified in the UK, holding an attestation de capacité in France, and in Spain with a certificado de gases fluorados and registered as a RITE installer.

The result

  • Cooling needed1,690 W
  • In BTU/h5,765 BTU/h
  • Room 1, living room: a 7,000 BTU/h (2 kW) unit1 unit

Common mistakes

  • Going by floor area alone. Rules of thumb per square metre miss the windows. A west-facing room with a big window can need twice the unit of a north-facing one the same size.
  • Leaving out the shading. Shutters or an awning outside stop about three quarters of the sun; blinds inside only about a third, since the heat is already in.
  • Adding the rooms up into one outdoor unit. The rooms don't all peak at once. A multi-split's outdoor unit is chosen by the installer, not by summing these.
  • Buying the biggest unit to be safe. An oversized unit cools in short bursts and leaves the air damp. The next size up from the load is the right one.
  • Counting on it for heating without checking. A unit's heating drops on cold days. If the check says it falls short, the room needs a bigger unit or another heat source.

Questions people ask

How many BTUs do I need for a room?

Add up the sun through each window, the heat through the walls and roof, the people, appliances and air, then multiply the watts by 3.412. The calculator shows every line of that working and the standard unit size it comes to.

What size air conditioner do I need for a bedroom?

Often a 7,000 or 9,000 BTU/h unit (2.0 or 2.5 kW), but it depends on its windows: a south- or west-facing bedroom under the roof can need 12,000. Enter the room and its windows to see.

How many frigorías do I need?

Frigorías per hour are kilowatts × 860, so a 2.5 kW unit is about 2,150 frigorías/h. With the region set to Spain, the result gives them too.

Can the same unit heat the room in winter?

Most split units are heat pumps, so yes, if its heating covers the room's heat loss on a cold day. The calculator checks each room, allowing for the unit giving less heat the colder it is outside, and says when a bigger unit or another heat source is needed.

Can I fit a split unit myself?

Not the refrigerant circuit: connecting and filling it is for a certified installer (F-gas in the UK, an attestation de capacité in France, a certificado de gases fluorados in Spain). A new circuit for it is electrical work; see our electrical guidance.

Can I fill it in from my floorplan?

Yes. Each room in the floorplan creator links here with its floor area, height, external walls and each window with the way it faces, from the north arrow on the plan. Set the north arrow first, and check the shading, which the plan doesn't know.